KM Regulations for Clearances and Works in the Vicinity of EHV Installations_Eng | Cable | Road

Publish in

Others

10 views
of 18
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Share
Description
Kahramaa Regulation
Tags
Transcript
  Issue : 006-02-2007Public Circulation -uncontrolledPage1of 18 EN-M1 K     A    HR     AMAA    Regul     ation    s for Cl     earances and     Works in the Vi    cinity of     E    x    tra-Hi     gh Voltage    In    stall     ation    s     KM Regulations for Clearances and Works in the Vicinity of Extra-High Voltage Installations EN-M1 Issue : 0 06-02-2007 Public Circulation - uncontrolled Page 2 of 18   Table of ContentsContents Page  Title Page1 Table of Contents2 PART ONE 1Introduction42Purpose43Responsibilities & Authorities44Definition of Terms45Articles5 PART TWO Introduction6 1Overhead Lines6 1.1General Requirements & Definitions61.2Roadways81.3Pipe-lines91.4Boundary Fences91.5Gardens & Landscaping101.6Street Lighting101.7Installations of Plant Outside the Way leavewhich May Influence EHV Services10    KM Regulations for Clearances and Works in the Vicinity of Extra-High Voltage Installations EN-M1 Issue : 0 06-02-2007 Public Circulation - uncontrolled Page 3 of 18 1.8Passage of High Loads under the OH Lines11 2Cable Circuits11 2.1General Requirements & Definitions112.2New Roadways132.3 Telephone, Water, Sewerage & Gas Services14 3Substations144 General Liabilities  15  Appendix A: EXPLANATORY NOTES CONCERNING EHV CABLEINSTALLATIONS   16    KM Regulations for Clearances and Works in the Vicinity of Extra-High Voltage Installations EN-M1 Issue : 0 06-02-2007 Public Circulation - uncontrolled Page 4 of 18 1. Introduction PART ONE  These Regulations are issued by KAHRAMAA (KM) under the authority established bythe Emiri Decree 2000. These Regulations were last updated on 6 February 2007. There is no expiry date for these Regulations other than subject to amendments byKAHRAMAA.   2. Purpose  The purpose of the regulations is to: ã Minimize the human cost to individuals, families and the general public of death, injury and destruction that can be caused by electricity; ã Prevent damage or interference to KAHRAMAA’s extra-high voltage (EHV)installations; ã Ensure safe and continuous supply of electricity. ã Ensure safe working practices by any person while working in the proximity of KAHRAMAA's EHV installations. The regulations are binding for entities, employers, employees, workers and persons inthe vicinity of KAHRAMAA’s EHV installations. The Regulations stipulate the conditions for execution of private and public serviceswork in the vicinity of EHV electricity installations. 3. Responsibilities & Authorities KAHRAMAA is the responsible and authority body for the enforcement, interpretationand update of these Regulations. The KAHRAMAA representative to be contactedfor all matters relating to these regulations is Electricity Networks Affairs - ENA. 4. Definition of Terms EHV Extra High Voltage , Covers voltage over 33kV. ENA Electricity Network Affairs, KAHRAMAA KM KAHRAMAA, Qatar General Electricity and Water Corporation
Related Search
Related Documents
View more...
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks